Adaptive low-impact hybrid islanding detection for grid-connected PV inverters in unbalanced and weak power systems
DOI:
https://doi.org/10.18686/cest803Keywords:
islanding detection; three-phase PV inverter; weak grid; voltage unbalance; negative sequence; proportional-resonant control; hybrid detection; IEEE (Institute of Electrical and Electronics Engineers) 1547Abstract
Whose fault tolerance, loading pattern, and balance vary over time. In such a feeder, an islanding detection method is expected to operate near the load-generator matching condition, tolerate practical background imbalance, and avoid unnecessary disturbance during normal service. This paper presents an analytical formulation, MATLAB-compatible time-domain numerical simulation, and parametric evaluation of a hybrid islanding detection algorithm for a 50 kW, 400 V, 50 Hz three-phase grid-connected PV inverter controlled by stationary-frame proportional-resonant (PR) current regulators. The proposed method uses a passive detection layer to enable a short negative-sequence reactive micro-probe injection. The injected signature is detected by correlating the measured negative-sequence voltage response against a normalized probe template. The paper defines the passive trigger condition, injected signature, normalized correlation detection metric, adaptive-gain injection procedure, power-quality bounds, latency requirements, and benchmarking configuration. The numerical simulation and parametric results are generated from the stated discrete-time detector model for different inverter ratings, probe amplitudes, gain settings, grid strengths, disturbance inputs, and correlation-response ratios. This evaluation also supports repeatable threshold selection, clarifies the trade-off between detection sensitivity and injected disturbance, and provides a reproducible basis for future EMT, HIL, field, controller, simulation, and multi-inverter validation studies.
References
1. Institute of Electrical and Electronics Engineers (IEEE). IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces. IEEE; 2018. doi: 10.1109/IEEESTD.2018.8332112
2. National Rural Electric Cooperative Association (NRECA). Guide to the IEEE 1547-2018 Standard and Its Impact on Cooperatives. NRECA; 2019. Available online: https://www.cooperative.com/programs-services/bts/documents/reports/nreca-guide-to-ieee-1547-2018-march-2019.pdf
3. Narang D, Ingram M, Hoke A, et al. Clause-by-Clause Summary of Requirements in IEEE 1547-2018. National Renewable Energy Laboratory; 2020. Available online: https://docs.nlr.gov/docs/fy20osti/75184.pdf
4. Bower W, Ropp M. Evaluation of Islanding Detection Methods for Photovoltaic Utility-Interactive Power Systems. International Energy Agency; 2002. Available online: https://iea-pvps.org/wp-content/uploads/2020/01/rep5_09.pdf
5. Bakhshi‐Jafarabadi R, Sadeh J, Serrano‐Fontova A, et al. Review on islanding detection methods for grid‐connected photovoltaic systems, existing limitations and future insights. IET Renewable Power Generation. 2022; 16(15): 3406–3421. doi: 10.1049/rpg2.12554
6. Kulkarni MS, Mishra S, Sudabattula SK, et al. Enhancing grid resiliency in distributed energy systems through a comprehensive review and comparative analysis of islanding detection methods. Scientific Reports. 2024; 14(1): 12124. doi: 10.1038/s41598-024-62690-z
7. Khan MA, Haque A, Kurukuru VSB, et al. Islanding detection techniques for grid-connected photovoltaic systems-A review. Renewable and Sustainable Energy Reviews. 2022; 154: 111854. doi: 10.1016/j.rser.2021.111854
8. Cebollero JA, Cañete D, Martín-Arroyo S, et al. A Survey of Islanding Detection Methods for Microgrids and Assessment of Non-Detection Zones in Comparison with Grid Codes. Energies. 2022; 15(2): 460. doi: 10.3390/en15020460
9. Larik NA, Tahir MF, Elbarbary ZMS, et al. A comprehensive literature review of conventional and modern islanding detection methods. Energy Strategy Reviews. 2022; 44: 101007. doi: 10.1016/j.esr.2022.101007
10. Alobaid M, Abo-Khalil AG. A comprehensive review and assessment of islanding detection techniques for PV systems. International Journal of Thermofluids. 2023; 18: 100353. doi: 10.1016/j.ijft.2023.100353
11. Zmood DN, Holmes DG. Stationary frame current regulation of PWM inverters with zero steady-state error. IEEE Transactions on Power Electronics. 2003; 18(3): 814–822. doi: 10.1109/TPEL.2003.810852
12. Teodorescu R, Blaabjerg F, Liserre M, et al. Proportional-resonant controllers and filters for grid-connected voltage-source converters. IEE Proceedings-Electric Power Applications. 2006; 153(5): 750–762. doi: 10.1049/ip-epa:20060008
13. Fortescue CL. Method of Symmetrical Co-Ordinates Applied to the Solution of Polyphase Networks. Transactions of the American Institute of Electrical Engineers. 1918; XXXVII(2): 1027–1140. doi: 10.1109/T-AIEE.1918.4765570
14. Zhang S, Wang L, Du X, et al. Improved Active Islanding Detection Technique with Different Current Injection Waveform. Processes. 2023; 11(6): 1838. doi: 10.3390/pr11061838
15. International Electrotechnical Commission (IEC). IEC/TR 61000-3-13: Electromagnetic Compatibility (EMC)—Part 3-13: Limits—Assessment of Emission Limits for the Connection of Unbalanced Installations to MV, HV and EHV Power Systems. IEC; 2008. Available online: https://cdn.standards.iteh.ai/samples/15428/40b93c44a4994edfb44fb2138637bde2/IEC-TR-61000-3-13-2008.pdf
16. Institute of Electrical and Electronics Engineers (IEEE). IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions. IEEE; 2010. doi: 10.1109/IEEESTD.2010.5439063
17. Gupta P, Bhatia RS, Jain DK. Impact of Reactive Current Injection by Islanding Detection Techniques on the Voltage Quality of Distributed Generation. In: Proceedings of the 2018 20th National Power Systems Conference (NPSC); 14–16 December 2018; Tiruchirappalli, India. pp. 1–6. Available online: https://www.iitk.ac.in/npsc/Papers/NPSC2018/1570475855.pdf
18. Emadi A, Sadeh J. Active islanding detection technique for inverter-based microgrids using optimized negative sequence disturbance injection. International Journal of Electrical Power & Energy Systems. 2025; 172: 111322. doi: 10.1016/j.ijepes.2025.111322
19. Ropp ME, Begovic M, Rohatgi A. Analysis and performance assessment of the active frequency drift method of islanding prevention. IEEE Transactions on Energy Conversion. 1999; 14(3): 810–816. doi: 10.1109/60.790956
20. Lopes LAC, Sun H. Performance Assessment of Active Frequency Drifting Islanding Detection Methods. IEEE Transactions on Energy Conversion. 2006; 21(1): 171–180. doi: 10.1109/TEC.2005.859981
21. Zeineldin HH, Kirtley JL. Performance of the OVP/UVP and OFP/UFP Method With Voltage and Frequency Dependent Loads. IEEE Transactions on Power Delivery. 2009; 24(2): 772–778. doi: 10.1109/TPWRD.2008.2002959
22. Khamis A, Shareef H, Bizkevelci E, et al. A review of islanding detection techniques for renewable distributed generation systems. Renewable and Sustainable Energy Reviews. 2013; 28: 483–493. doi: 10.1016/j.rser.2013.08.025
23. Mastromauro RA. Grid Synchronization and Islanding Detection Methods for Single-Stage Photovoltaic Systems. Energies. 2020; 13(13): 3382. doi: 10.3390/en13133382
24. Abu Sarhan M. An Extensive Review and Analysis of Islanding Detection Techniques in DG Systems Connected to Power Grids. Energies. 2023; 16(9): 3678. doi: 10.3390/en16093678
25. Chmielowiec K, Piszczek A, Topolski Ł. Experimental Insights into Islanding Detection in PV Inverters: Foundations for a Parallel-Operation Test Standard. Sensors. 2025; 25(24): 7582. doi: 10.3390/s25247582
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Abdel-Rahman Al Qawasmi

This work is licensed under a Creative Commons Attribution 4.0 International License.




.jpg)
.jpg)